Registered Ophthalmic Ultrasound Biometrist Exam Prep
Free practice questions

Free ROUB Practice Questions

10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.

Start the free practice test → ★★★★★4.9/5 from 2,400+ candidates · No signup

These 10 free ROUB questions are organized by exam domain, so you can see how each part of the Registered Ophthalmic Ultrasound Biometrist blueprint is tested. Reveal the answer and explanation under each question.

Domain 1: Keratometry 5% of exam

Question 1

Repeatable keratometry shows a radius of 7.50 mm in the 90-degree meridian and 8.00 mm in the 180-degree meridian. The cornea has regular astigmatism. Using K = 337.5/r, with r in millimeters, the keratometric astigmatism should be recorded as:

Show answer & explanation

Correct answer: D - 2.81 D, with the steep meridian at 90 degrees

Domain 2: Physics 16% of exam

Question 2

An immersion A-scan records echo arrivals 2 microseconds after transmission at the cornea, 6 at the anterior lens surface, 12 at the posterior lens surface, and 36 at the retina. The vitreous sound velocity is 1,532 m/s. Using distance in mm = velocity in m/s x round-trip time in microseconds / 2,000, which interval and result belong to the vitreous chamber?

Show answer & explanation

Correct answer: C - Posterior lens surface to retina: 18.38 mm

Question 3

During a probe test, two closely spaced reflectors lie one behind the other along the ultrasound beam. Their returns merge into one broad echo even though the beam is sharply focused at that depth. Which change would help resolve the two reflectors?

Show answer & explanation

Correct answer: C - Increase damping to shorten the transmitted pulse.

Domain 3: Biometry Instrumentation 11% of exam

Question 4

A patient with a dense cataract cannot obtain a valid axial-length reading on the clinic's optical biometer despite correct positioning and repeated attempts. The ophthalmologist has completed the posterior-segment assessment and requested biometry. A calibrated ultrasound biometer and immersion equipment are available. How should axial length be obtained at this visit?

Show answer & explanation

Correct answer: A - Perform immersion A-scan biometry and inspect the acquired traces.

Domain 4: Instrument Settings for Biometry 13% of exam

Question 5

A well-aligned phakic A-scan has a clearly identifiable posterior lens echo that falls just below the capture threshold. The anterior lens and retinal echoes are already near the top of the display. The biometer provides separate gain controls for each of these three interfaces. The most targeted adjustment is to:

Show answer & explanation

Correct answer: B - Increase posterior-lens gain while leaving the other two gains unchanged.

Domain 5: Examination Techniques for Biometry 18% of exam

Question 6

Before a scheduled contact A-scan, a patient reports that a metal fragment struck the eye that morning. Vision has suddenly worsened, and the pupil appears peaked toward a visible corneal wound. What is the immediate priority?

Show answer & explanation

Correct answer: D - Avoid ocular pressure and obtain immediate ophthalmic assessment.

Question 7

In an eye with a documented posterior staphyloma, independently repeated immersion scans measure 29.10 mm along the verified foveal path and 30.20 mm when the beam is directed toward the deepest, eccentric part of the staphyloma. Both sets have sharp echoes. Which measurement belongs in the IOL calculation?

Show answer & explanation

Correct answer: A - The 29.10-mm measurement along the verified foveal path

Domain 6: Sources of Error in Biometry 22% of exam

Question 8

Contact A-scan of a phakic eye gives an axial length of 23.46 mm and an anterior chamber depth of 2.82 mm. Careful immersion measurements give 23.82 mm and 3.18 mm, respectively. Lens thickness and vitreous chamber depth agree. The corneal start and other anatomical interfaces are correctly identified in both sets. What best accounts for the paired change?

Show answer & explanation

Correct answer: B - The contact probe indented the cornea during acquisition.

Question 9

A phakic eye has a vitreous cavity completely filled with silicone oil. The anterior-cornea-to-lens depth of 3.20 mm and lens thickness of 4.30 mm have been measured correctly. The vitreous segment displays 27.576 mm because it was converted at 1,532 m/s instead of the specified oil velocity of 980 m/s. All interfaces are correctly identified, and no oil correction has been applied. Which corrected axial length is supported by these measurements?

Show answer & explanation

Correct answer: C - 25.14 mm

Domain 7: Intraocular Lens Power Calculations 15% of exam

Question 10

Years after myopic LASIK, a patient is being evaluated for cataract surgery. Axial length is reliable, but conventional anterior-surface keratometry overestimates the eye's true corneal power. If that uncorrected corneal power is used in an otherwise appropriate calculation for a positive-power IOL, what refractive error does this specific bias tend to produce, and why?

Show answer & explanation

Correct answer: A - Hyperopia, because the calculated IOL power is too low.

That's 10 of 1,030

The full bank has 1,020 more ROUB questions with explanations.

Continue in the free practice test →